Featured Video
This Week in Quality Digest Live
Innovation Features
Dirk Dusharme @ Quality Digest
Keeping bad bots out and good data to ourselves
Jeffrey Phillips
An appropriate amount of good failure (early) can eliminate bad failure (late)
Knowledge at Wharton
A ‘different type of chassis’ for improving healthcare delivery
Dirk Dusharme @ Quality Digest
Really. We don’t.
Frank Defesche
We all need the skills to adopt manufacturing technology suited for today’s realities

More Features

Innovation News
IoT solution includes advanced lab testing and real-world crowd testing
New system patches security holes left open by web browsers’ private-browsing functions
125 strategies to achieve maximum confidence, clarity, certainty, and creativity
MIT awards more than $1 million to organizations creating greater economic opportunity for workers
Berkeley Lab and Magic Leap Inc. scientists create widely controllable ultra thin optical components
$79 device delivers dedicated neural network processing to a range of host devices
Drip irrigation targets the plant and not the soil
New approach uses light instead of electricity
If you want to understand a system, try and change it

More News

NIST

Innovation

Thinking Outside the Cuvette

To measure the dimensions of the skinny glass container, NIST’s PML scientists get creative

Published: Tuesday, February 16, 2016 - 12:26

Let’s say you’re a biotechnologist working to develop new medicines or a better test for forensic analysis. You might find yourself frequently using absorbance spectroscopy, a technique that allows researchers to identify even small amounts of a substance (such as DNA) or an antibody based on how it absorbs light.

To support these kinds of day-to-day measurements by people in the biotechnology community, NIST’s Material Measurement Laboratory (MML) recently developed a new standard reference material (SRM) designed for use with samples where only a small amount of the material is available. The new NIST resource, called SRM 2082, consists of two separate solutions, one of tryptophan, an amino acid, and one of uracil, a nucleic acid found in RNA.


Wei Ren with the triangulation probe and a cuvette. J.L. Lee/PML

But before MML staff could release its SRM to a waiting biotechnology community, they required an ultra-accurate determination of the width of the NIST cuvettes, which are tiny containers used in the certification process. The width of the cuvettes determines the pathlength that light travels through these solutions. (The certified property of SRM 2082 is an equation that relates the pathlength of light through these solutions to their absorbance.) To do so, they called on a team of dimensional metrologists from NIST’s Physical Measurement Laboratory (PML).

Nominally, each miniature cuvette is 45 mm long by 10 mm wide—smaller than a typical thumb drive—with three different possible pathlengths: 2 mm, 1 mm, and 0.5 mm. However, “due to geometric imperfections, this gap between the walls of the cuvette varies slightly as a function of location,” says PML Engineering Physics Division’s Wei Ren. “To reduce uncertainties in the measurements of these standards, MML needed to have a rigorous characterization of the dimensions of the gap for each cuvette.”

The gold standard for this type of measurement is a high-accuracy coordinate measuring machine (CMM), whose hard probe tip physically touches the surface of an object to assess its dimensions, Wei explains. But in this case, alas, a CMM was out of the question.

The big challenge, Wei explains, was the large length-to-width ratio of the cuvettes. Although she had probe tips of the correct size, the smaller tips required shorter shafts to maintain proper stiffness, and those shafts were too stubby to reach the bottoms of the containers.

Wei considered other options. She often used laser triangulation probing, a noncontact technique, to measure the dimensions of ceramic or other opaque surfaces. The method involves shining a fat laser spot onto the surface of an object and collecting the incident light through a lens, which then focuses it onto a charge-coupled device (CCD). The position of the beam spot on the CCD varies with the distance to the object at that measurement point, as seen in the diagram below.


A diagram with a basic illustration of laser triangulation probing. The laser was angled for the cuvette measurement setup. Original diagram licensing information: “Laserprofilometer EN” by Georg Wiora (Dr. Schorsch). Self-made drawing. Licensed under CC BY-SA 3.0 via Commons. Changes to original diagram by J. L. Lee/PML.

Though she had never used the method with transparent glass, Wei found a workaround: Instead of shining laser light straight down onto the cuvette, she shone it at a 20° angle. At each of the four interfaces between air and glass, the light was reflected back to the CCD detector. With this information, a computer program was able to work out the distances between each of the interfaces—in particular, between the two glass inner walls that determine each cuvette’s “gap.”

Wei used laser triangulation to probe the gap of each cuvette at 6-mm intervals. Because these were not absolute measurements, she backed up her findings by comparing at least part of each cuvette to measurements made with a standard touch probe, the NIST M48 CMM.

Her measurements yielded uncertainties of less than 1 micrometer (millionth of a meter). With this information, the MML team’s resulting expanded uncertainty of the absorbance of the materials, as a function of pathlength, is less than 0.08 percent.

“We spent a lot of time unsuccessfully trying to come up with a ‘complete probing’ solution for this small, high-aspect ratio measurement,” says Eric Stanfield, Measurement Services project leader in PML’s Dimensional Metrology Group. “Just when we thought we were out of options, Wei delivered success for the team by coming up with this alternative approach that combined probing and a noncontact technique that worked remarkably well.”


A cuvette with a 2-mm gap length, illuminated with a laser spot (red) from the triangulation probe. J.L. Lee/PML

“Measurement challenges are what make dimensional metrology so exciting and the ability to find creative solutions is almost a prerequisite for the job,” says Stanfield.

The new SRM 2082 is expected to be released by April 2016.

Discuss

About The Author

NIST’s picture

NIST

Founded in 1901, The National Institute of Standards and Technology (NIST) is a nonregulatory federal agency within the U.S. Department of Commerce. Headquartered in Gaithersburg, Maryland, NIST’s mission is to promote U.S. innovation and industrial competitiveness by advancing measurement science, standards, and technology in ways that enhance economic security and improve our quality of life.